Error description
Business-level application (BLA) code plugs into the application management deployment framework to create a BLA and composition unit (CU) for the new application. After it does that, more tasks added by the product extension run and fail, and the BLA and CU are left hanging around. The sceanrio is a failed deployment and the session is then saved. If the session is discarded or if the deployment succeeds, things work correctly. So, the problem is that a failed deployment is not leaving the work space clean. No warning is issued to notify the user.
Local fix
Remove any directories or files created, clean work space.
http://www-01.ibm.com/support/docview.wss?uid=swg1PM20642CUS folder path
<WAS_HOME>/profiles/<dmgr>\Dmgr01\config\cells\<CellName>\cus
BLAS folder path
<WAS_HOME>/profiles/<dmgr>\Dmgr01\config\cells\<CellName>\blas
--
Thanks and Regards
Bhaskar Ramaraju
http://www.linkedin.com/in/ramarajubhaskar